Influence of intraoral scanner and finish line location on the fabrication trueness and margin quality of additively manufactured laminate veneers fabricated with a completely digital workflow

dc.authorid0000-0002-3094-7487
dc.authorid0000-0002-7101-363X
dc.authorid0000-0002-9597-6342
dc.authorid0000-0001-9700-5534
dc.authorid0000-0003-1751-9207
dc.contributor.authorCakmak, Guelce
dc.contributor.authorChebaro, Jad
dc.contributor.authorDonmez, Mustafa Borga
dc.contributor.authorYilmaz, Deniz
dc.contributor.authorYoon, Hyung-In
dc.contributor.authorKahveci, Cigdem
dc.contributor.authorSchimmel, Martin
dc.date.accessioned2026-01-24T12:31:17Z
dc.date.available2026-01-24T12:31:17Z
dc.date.issued2024
dc.departmentAlanya Alaaddin Keykubat Üniversitesi
dc.description.abstractStatement of problem. Knowledge of the fabrication trueness and margin quality of additively manufactured (AM) laminate veneers (LVs) when different intraoral scanners (IOSs) and finish line locations are used is limited. Purpose. The purpose of this in vitro study was to evaluate the fabrication trueness and margin quality of AM LVs with different finish line locations digitized by using different IOSs. Material and methods. An LV preparation with a subgingival (sub), equigingival (equi), or supragingival (supra) finish line was performed on 3 identical maxillary right central incisor typodont teeth. Each preparation was digitized by using 2 IOSs, (CEREC Primescan [PS] and TRIOS 3 [TS]), and a reference LV for each finish line-IOS pair (n=6) was designed. A total of 90 LVs were fabricated by using these files and urethane acrylate-based definitive resin (Tera Harz TC-80DP) (n=15). Each LV was then digitized by using PS to evaluate fabrication trueness (overall, external, intaglio, and marginal surfaces). Each LV was also qualitatively evaluated under a stereomicroscope (x60), and the cervical and incisal margin quality was graded. Fabrication trueness and cervical margin quality were evaluated by using 2 -way analysis of variance, while Kruskal-Wallis and Mann Whitney -U tests were used to evaluate incisal margin quality (alpha=.05). Results. The interaction between the IOS type and the finish line location affected measured deviations at each surface (P <=.020). PS -sub and TS -supra had higher overall trueness than their counterparts. and the subgingival finish line resulted in the lowest trueness (P <=.005). PS and the subgingival finish line led to the lowest trueness of the external surface (P <=.001). TS -sub had the lowest intaglio surface trueness among the TS subgroups, and PS -sub had higher trueness than TS -sub (P<.001). PS -sub and PS -supra had higher marginal surface trueness than their TS counterparts (P<.001). TS resulted in higher cervical margin quality (P=.001). Conclusions. Regardless of the IOS tested, subgingival finish lines resulted in the lowest trueness. The effect of IOS on the measured deviations varied according to the surface evaluated and finish line location. The cervical margin quality of AM LVs was higher when TS was used. (J Prosthet Dent 2024;131:313.e1 -e9)
dc.identifier.doi10.1016/j.prosdent.2023.10.026
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue2
dc.identifier.pmid37978007
dc.identifier.scopus2-s2.0-85180432833
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2023.10.026
dc.identifier.urihttps://hdl.handle.net/20.500.12868/5781
dc.identifier.volume131
dc.identifier.wosWOS:001188810900001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMosby-Elsevier
dc.relation.ispartofJournal of Prosthetic Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260121
dc.subjectMicroleakage
dc.subjectAccuracy
dc.subjectCrowns
dc.titleInfluence of intraoral scanner and finish line location on the fabrication trueness and margin quality of additively manufactured laminate veneers fabricated with a completely digital workflow
dc.typeArticle

Dosyalar