A new error reduction technique for reflection coefficient measurements for use in quick laboratory tests

dc.contributor.authorÇolak, Bektaş
dc.contributor.authorHelhel, Selçuk
dc.date.accessioned2021-02-19T21:16:20Z
dc.date.available2021-02-19T21:16:20Z
dc.date.issued2019
dc.departmentALKÜ
dc.descriptionHELHEL, SELCUK/0000-0002-1401-3297
dc.description.abstractReflection coefficient measurement is one of those fundamental methods for determining the performance of radar absorber materials, and reflections due to these measurements are originated from the discontinuities in the measurement system and they result in error. In this paper, a new technique for the calibration of the scalar reflection coefficient measurements in the frequency range of 3-18 GHz in a portable two-sectioned metallic chamber is being proposed for use in quick laboratory tests with reasonable error (redacted error). Calibration measurements are performed by two calibration standards in frequency domain and transformed to time domain for further calculation. Proposed technique exhibits a good agreement with the theoretical values for especially in compact chambers where plane-wave conditions are not fully satisfied, and it is not in need of any complex time gating process. Furthermore, it does not require considering the phase differences which occurs at the measurement plane, providing a cheap and faster solution, reducing time and complexity in characterization of radar absorber materials. This technique with the mentioned test set-up could supply scalar reflection coefficient measurements with overall 0.55 dB error level and useful for practical applications where high level of accuracy is not required.
dc.description.sponsorshipDevlet Planlama Orgutu [2007K120530-DPT]
dc.description.sponsorshipThis work was supported by the Devlet Planlama Orgutu [2007K120530-DPT].
dc.identifier.doi10.1080/00207217.2018.1523473
dc.identifier.endpage249en_US
dc.identifier.issn0020-7217
dc.identifier.issn1362-3060
dc.identifier.issue2en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage237en_US
dc.identifier.urihttps://doi.org/10.1080/00207217.2018.1523473
dc.identifier.urihttps://hdl.handle.net/20.500.12868/383
dc.identifier.volume106en_US
dc.identifier.wosWOS:000451611800004
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthor0-belirlenecek
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofInternational Journal of Electronics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectScalar reflection coefficient measurement
dc.subjectradar-absorbing material
dc.subjecttime gating
dc.subjecterror reduction
dc.subjectcalibration
dc.titleA new error reduction technique for reflection coefficient measurements for use in quick laboratory tests