Load-carrying capacity of filament-wound E glass/epoxy composite rings

[ X ]

Tarih

2019

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Csme Trans

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, three different types of E glass/epoxy composite rings were produced by the filament-winding technique: (i) O ring (Type A), (ii) ring with a radial notch (Type B), and (iii) C-shaped ring (Type C). To evaluate the effect of winding angle on the load-carrying capacity of composite rings, five different winding angles were considered: +/- 45 degrees, +/- 55 degrees, +/- 65 degrees, +/- 75 degrees, and +/- 88 degrees. The load capacity of the manufactured composite rings in the tensile hoop direction were determined experimentally using a special test fixture. The experimental results showed that the optimum winding angle was +/- 88 degrees in terms of load-carrying capacity. The rings wound at 55 degrees had the lowest load-carrying capacity. Type A rings had the highest capacity while Type C rings had the lowest.

Açıklama

Beylergil, Bertan/0000-0002-3204-6746

Anahtar Kelimeler

composite, filament winding, ring, strength, hoop testing

Kaynak

Transactions of the Canadian Society For Mechanical Engineering

WoS Q Değeri

N/A

Scopus Q Değeri

Q3

Cilt

43

Sayı

2

Künye