A numerical study on the effect of vent/wall area ratio on Trombe wall thermal performance

dc.authorid0000-0002-1098-6534
dc.authorid0000-0002-6257-1306
dc.authorid0000-0002-6456-4396
dc.contributor.authorKaya, Ercan Serif
dc.contributor.authorAksel, Murat
dc.contributor.authorYigit, Sadik
dc.contributor.authorAcikara, Turgut
dc.date.accessioned2026-01-24T12:29:18Z
dc.date.available2026-01-24T12:29:18Z
dc.date.issued2021
dc.departmentAlanya Alaaddin Keykubat Üniversitesi
dc.description.abstractTrombe walls are the most widely applied passive systems that utilise solar energy for heating massive walls. Although studies have been undertaken in the fields of Trombe wall application and design, the research on the effect of the vent area and the number of vents on the performance of a Trombe wall remains limited. In this context, a parametric study investigating the effect of the vent-to-wall-area ratio on Trombe wall performance was conducted. A computational fluid dynamics model was employed for validation analysis. The results were verified by experimental measurements of temperature. At each step of the parametric study, the vent-to-wall-area ratio in the Trombe wall model was increased by 2% starting from the unvented case, and the results were simulated per ratio. In this study, temperature measurements of the glazing, thermal wall and space were employed as the evaluation criteria. The results of the parametric runs showed that a Trombe wall with eight separate air vents and an 8% vent-to-wall-area ratio provides the maximum heating performance. Furthermore, a monolithic vent configuration with an 18% vent-to-wall-area ratio performed slightly better compared with other configurations of monolithic air vents.
dc.identifier.doi10.1680/jensu.20.00064
dc.identifier.endpage234
dc.identifier.issn1478-4629
dc.identifier.issn1751-7680
dc.identifier.issue5
dc.identifier.scopus2-s2.0-85117716348
dc.identifier.scopusqualityQ2
dc.identifier.startpage224
dc.identifier.urihttps://doi.org/10.1680/jensu.20.00064
dc.identifier.urihttps://hdl.handle.net/20.500.12868/5245
dc.identifier.volume174
dc.identifier.wosWOS:000710163300003
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherEmerald Group Publishing Ltd
dc.relation.ispartofProceedings of The Institution of Civil Engineers-Engineering Sustainability
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260121
dc.subjectenergy conservation
dc.subjectsustainability
dc.subjectthermal effects
dc.titleA numerical study on the effect of vent/wall area ratio on Trombe wall thermal performance
dc.typeArticle

Dosyalar