Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period
| dc.contributor.author | Sayin Ozel, Gülsüm | |
| dc.contributor.author | Inan, Özgür | |
| dc.contributor.author | Secilmis, Asli | |
| dc.contributor.author | Iyidogan, Gamze Alniacik | |
| dc.contributor.author | Dolanmaz, Do?an | |
| dc.contributor.author | Yildirim, Gülsün | |
| dc.date.accessioned | 2026-01-24T12:20:50Z | |
| dc.date.available | 2026-01-24T12:20:50Z | |
| dc.date.issued | 2021 | |
| dc.department | Alanya Alaaddin Keykubat Üniversitesi | |
| dc.description.abstract | Background. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA). Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n = 25) or modified (SLActive) surface properties (n = 25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time. Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P < 0.05). Stability improved each week except in the 4th week in SLActive surface measurements. No significant differences were observed between the groups at 2 and 3 months (P > 0.05). Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups. © 2021 The Author(s). | |
| dc.identifier.doi | 10.34172/joddd.2021.037 | |
| dc.identifier.endpage | 231 | |
| dc.identifier.issn | 2008-210X | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85125638571 | |
| dc.identifier.scopusquality | Q4 | |
| dc.identifier.startpage | 226 | |
| dc.identifier.uri | https://doi.org/10.34172/joddd.2021.037 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12868/4619 | |
| dc.identifier.volume | 15 | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Tabriz University of Medical Sciences | |
| dc.relation.ispartof | Journal of Dental Research, Dental Clinics, Dental Prospects | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_Scopus_20260121 | |
| dc.subject | Bone-implant interface | |
| dc.subject | Dental implants | |
| dc.subject | Osseointegration | |
| dc.subject | Resonance frequency analysis | |
| dc.subject | SLA | |
| dc.subject | SLActive | |
| dc.title | Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period | |
| dc.type | Article |