Stability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period

dc.contributor.authorSayin Ozel, Gülsüm
dc.contributor.authorInan, Özgür
dc.contributor.authorSecilmis, Asli
dc.contributor.authorIyidogan, Gamze Alniacik
dc.contributor.authorDolanmaz, Do?an
dc.contributor.authorYildirim, Gülsün
dc.date.accessioned2026-01-24T12:20:50Z
dc.date.available2026-01-24T12:20:50Z
dc.date.issued2021
dc.departmentAlanya Alaaddin Keykubat Üniversitesi
dc.description.abstractBackground. The surface properties of implants are effective factors for increasing the osseointegration and activity of osteoprogenitor cells. This study compared the stability of dental implants with sandblasted and acid-etched (SLA) and modified surfaces (SLActive) using the resonance frequency analysis (RFA). Methods. In a split-mouth design, 50 dental implants with either SLA surface properties (n = 25) or modified (SLActive) surface properties (n = 25) were placed in the mandibles of 12 patients with a bilateral posterior edentulous area. Implant stability was measured using RFA (Osstell) at implant placement time and every week for 1, 2, and 3 months before the conventional loading time. Results. One week following the implantation, implant stability increased from 70 to 77.67 for SLA and from 71.67 to 79 for SLActive (P < 0.05). Stability improved each week except in the 4th week in SLActive surface measurements. No significant differences were observed between the groups at 2 and 3 months (P > 0.05). Conclusions. For both implant surfaces, increased stability was observed over time, with no significant differences between the groups. © 2021 The Author(s).
dc.identifier.doi10.34172/joddd.2021.037
dc.identifier.endpage231
dc.identifier.issn2008-210X
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85125638571
dc.identifier.scopusqualityQ4
dc.identifier.startpage226
dc.identifier.urihttps://doi.org/10.34172/joddd.2021.037
dc.identifier.urihttps://hdl.handle.net/20.500.12868/4619
dc.identifier.volume15
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTabriz University of Medical Sciences
dc.relation.ispartofJournal of Dental Research, Dental Clinics, Dental Prospects
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20260121
dc.subjectBone-implant interface
dc.subjectDental implants
dc.subjectOsseointegration
dc.subjectResonance frequency analysis
dc.subjectSLA
dc.subjectSLActive
dc.titleStability of dental implants with sandblasted and acid-etched (SLA) and modified (SLActive) surfaces during the osseointegration period
dc.typeArticle

Dosyalar