Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Ocak, Hakan" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Which dental implant surface is more effective in osteointegration: RBM surface versus SLA surface
    (2021) Demetoğlu, Umut; Ocak, Hakan; Songür, Timur; Çolpak, Halis Ali
    Aim: The surface characteristics of an implant direct the wound healing and are an important factor for osteointegration. There are very few studies evaluating or comparing the clinical success of osteointegration of sandblasting with larger grit and acid etching (SLA) and rough surface as required by grit blasting (RBM) surfaces, which are important surface factors in selecting an implant. The aim of this study was to evaluate the osteointegration success in a total of 4793 implants in 2005 patients in SLA and RBM surface cylindrical implants of the same trademark and type. Material and Methods: A total of 4793 implants and 2005 patients composed of 943 females and 1062 males were included in this study. Regions of implant applications were grouped into anterior and posterior parts of the mandible and anterior and posterior parts of the maxilla and evaluated with success rates. Results: Among the implants, 1877 were RBM surface and the remaining 2675 had SLA surface. Seventy-four implants among the 1877 RBM surface implants failed (%96.06). The success rates were 94.75 % and 97.22%, maxilla and mandible, respectively. Among the 2675 SLA surface implants, 93 failed (%96.53). The success rates were 95.29% and 97.11% in maxilla and mandible, respectively. Discussion: Recently, the studies have demonstrated increased bone and implant contact areas and a high degree of osteoconductive property when applied to surfaces in histological studies. In the presented study, RBM and SLA surface implants with the same trademark and same design were clinically compared, and no significant difference was found between them in terms of osteointegration success.

| Alanya Alaaddin Keykubat Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Alanya Alaaddin Keykubat Üniversitesi, Alanya, Antalya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim