Yazar "Karaburun, Murat Can" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Sexual dysfunction in women with interstitial cystitis/bladder pain syndrome: Do onabotulinum toxin-A injections improve sexual function?(John Wiley and Sons Inc, 2023) Topçuoglu, Murat; Karaburun, Murat Can; İbiş, Arif Halil; Gökçe, Mehmet İlker; Süer, Evren; Gülpınar, ÖmerIntroduction: Interstitial cystitis/bladder pain syndrome (IC/BPS) has a negative impact on female sexual function. We aimed to evaluate the effect of intravesical botulinum toxin-A (BTX-A) injection on the improvement of sexual dysfunction and urinary symptoms using the multi-domain female sexual function Index (FSFI), interstitial cystitis symptom index (ICSI), and interstitial cystitis problem index (ICPI). Material and Method: The data of the 23 patients (study group) who received intravesical BTX-A with the diagnosis of IC/BPS were reviewed. Twenty-three age-matched healthy, sexually active women were determined as the control group. Patients received 100 U BTX-A submucosally injections, including the trigone. One hundred units of BTX-A were diluted to 20 cc 0.9% saline, and 1 cc was then applied submucosally on 20 different points of the bladder wall (5 U/1 mL per site). The study group was asked to fill out FSFI, ICSI, and ICPI, as well as the visual analog scale (VAS) and bladder diary before and 3 months after the treatment. Patients in the control group completed the same questionnaires once. The pre- and post-treatment questionnaire scores were compared in the study group. The study group's data were also compared to the control group. Results: Compared to the pretreatment period, the study group showed statistically significant improvement in the total FSFI score and each domain of the FSFI after BTX-A injection. The mean total FSFI score and three domains of FSFI (desire, lubrication, pain) reached to the score of the control group following BTX-A injection. Statistically significant improvements were also shown in scores of ICSI, ICPI, and VAS. (p < 0.05). Conclusion: IC/BPS is associated with a very high incidence of sexual dysfunction. Intravesical BTX-A injection may provide significant improvement in sexual dysfunction in women with IC/BPS. © 2023 Wiley Periodicals LLC.Öğe Simultaneous uroflowmetry and urinalysis with single specimen - A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device(Cell Press, 2023) Topcuog, Murat; Karaburun, Murat Can; Sanci, Adem; Kokurcan, Ozden; Devrim, Erdinc; Gulpinar, OmerObjective: To evaluate the consistency of the urinalysis results performed with the ORUBA INALYS device, (Oruba, Ankara, Turkey) which can perform urinalysis and uroflowmetry simultaneously, with the analysis results performed with the SYSMEX UC3500 automated urine chemistry analyzer (Sysmex, Kobe, Japan). Material and methods: In this prospective study, urinalysis of 50 male patients with lower urinary tract symptoms were evaluated. The parameters of glucose, pH, urobilinogen, bilirubin and ketone, leukocyte, protein, and blood were measured with ORUBA INALYS, and the same urine specimens collected from ORUBA INALYS by a special setup were sent to the laboratory for urinalysis with Sysmex UC-3500 to assess the concordance of the results between two devices. Results: Urinalysis results in ORUBA INALYS device in terms of glucose, pH, urobilinogen, bilirubin, and ketone parameters were shown to achieve 100% agreement within +/- 1 category with SYSMEX UC3500 whereas these values were slightly decreased to 88%, 96%, and 98% for leukocyte, protein, and blood, respectively. Among the calculable weighted kappa values for the test parameters, the highest value was found for glucose and followed by blood, pH, leukocyte, and specific gravity respectively. Conclusion: Significant consistency of the urinalysis results obtained from ORUBA INALYS with those obtained from device SYSMEX UC3500 shows the reliability of the urinalysis performed with ORUBA INALYS. ORUBA INALYS could minimize costs and workload, provide time save and reduce plastic waste.












