Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Bozoglan, Alihan" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    Effects of local enemal matrix protein on osseointegration of different surface Titanium implants
    (Univ Zulia, Facultad Ciencias Veterinarias, 2025) Istek, Ozmen; Sokmen, Kevser; Ozcan, Erhan Cahit; Tanrisever, Murat; Gelic, Turker; Can, Umit Koray; Bozoglan, Alihan
    The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300-350 g were included in the study as subjects. The rats were divided into 3 groups with 10 rats in each group: Machined Surface Group (n = 10), Sandblasted Large Acid Grid (SLA) Surface Group (n = 10) and Resorbable Blasting Material (RBM) Surface Group (n = 10). Titanium implants were surgically placed in the right tibias of the rats with sterile physiological serum cooling. Immediately before the implants were placed, local enamel matrix protein was applied to the prepared sockets and then the implants were placed. The rats were euthanized after waiting for osseointegration for four weeks and the implants were taken with the surrounding bone tissues after the soft tissues were removed. The bone-implant contact of all implants was analyzed by biomechanical method and recorded in Newtoncm-1(Ncm-1). When the obtained biomechanical data were examined, the average bone-implant contact value was found to be 2.24 +/- 0.67 (Ncm-1) in machined surface implants, 4.5 +/- 1.36 (Ncm-1) in SLA surface implants and 3.24 +/- 0.94 (Ncm-1) in RBM surface implants. A statistically difference was detected between machined surface implants and SLA surface implants (P<0.05; P=0.02). It can be stated that local enamel matrix protein application may increase bone-implant connection in SLA surface implants.

| Alanya Alaaddin Keykubat Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Alanya Alaaddin Keykubat Üniversitesi, Alanya, Antalya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim