Basit öğe kaydını göster

dc.contributor.authorAtız, Ayhan
dc.contributor.authorKarakılcık, Hatice
dc.contributor.authorErden, Mustafa
dc.contributor.authorKarakılcık, Mehmet
dc.date.accessioned2021-02-19T21:16:23Z
dc.date.available2021-02-19T21:16:23Z
dc.date.issued2019
dc.identifier.issn0196-8904
dc.identifier.issn1879-2227
dc.identifier.urihttps://doi.org/10.1016/j.enconman.2019.05.056
dc.identifier.urihttps://hdl.handle.net/20.500.12868/406
dc.descriptionKarakilcik, Hatice/0000-0002-8622-1490; ATIZ, AYHAN/0000-0002-1292-5161en_US
dc.descriptionWOS: 000482244300065en_US
dc.description.abstractIn this work, energy, exergy and electricity generation performance of an integrated system was conceptually investigated by using Engineering Equation Solver (EES) under 200-1000 W/m(2) solar irradiation interval. The system comprises evacuated tube solar collectors (EVTSCs) with the surface area of 100 m(2), an organic Rankine cycle (ORC) and a low-grade geothermal resource. The EVTSCs were used to enhance the temperature of the low-grade water coming from the geothermal source. The calculations were carried out for three geothermal sources in Kula (63 degrees C), Saraycik (74 degrees C) and Turgutlu (86 degrees C), respectively. N-hexane, n-pentane and n-butane were selected as a working fluid in the ORC. It was determined that the selection of the working fluid affected the performance of the ORC. And also, the waste heat is extracted from the ORC were used efficiently for space heating. As a result, the overall energy and exergy efficiencies of the system and power generation of the ORC were seriously affected by enhancing the water temperature of the geothermal resources by EVTSCs. The maximum overall energy and exergy efficiencies of the system were calculated as to be 6.92% and 21.06% by using n-butane for the source in Turgutlu, respectively. The minimum overall energy and exergy efficiencies of the system were calculated as 0.32% and 2.19% by using n-hexane for the source in Kula, respectively. The maximum and minimum generated electricity were calculated as to be 19.46 kW and 0.6168 kW for the sources in Turgutlu and Kula, respectively. It was seen that the best performance of the system was found for n-butane compared to n-pentane and n-hexane.en_US
dc.language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectLow-grade geothermal sourceen_US
dc.subjectEvacuated tube solar collectorsen_US
dc.subjectOrganic Rankine cycleen_US
dc.subjectPower generationen_US
dc.subjectEnergy and exergy efficiencyen_US
dc.titleInvestigation energy, exergy and electricity production performance of an integrated system based on a low-temperature geothermal resource and solar energyen_US
dc.typearticleen_US
dc.contributor.departmentALKÜen_US
dc.contributor.institutionauthor0-belirlenecek
dc.identifier.doi10.1016/j.enconman.2019.05.056
dc.identifier.volume195en_US
dc.identifier.startpage798en_US
dc.identifier.endpage809en_US
dc.relation.journalEnergy Conversion And Managementen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.