Basit öğe kaydını göster

dc.contributor.authorKarcı, Bilge
dc.contributor.authorÖncü, Elif
dc.date.accessioned2022-09-14T13:22:02Z
dc.date.available2022-09-14T13:22:02Z
dc.date.issued2021en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12868/1622
dc.description.abstractObjectives: This study aimed to evaluate the levels of TNF-alpha, PGE., RANKL, RANK, OPG, the markers of periimplant bone toss in peri-implant crevicutar fluid obtained around standard and extra short implants. Moreover, the levels of putative oral pathogens were investigated in the submucosal biofilm samples. Material and Methods: The implants were divided into two groups according to their Lengths: standard (>= 8 mm) and extra short (4 mm). A total of 60 implants were researched in 30 patients. The probing depth (PD), clinical attachment level (CAL), presence of bleeding on probing (BOP), 3-year survival rate (CSR), and bone toss (BL) were measured. Results: No statistically significant difference was found in the values of PD, CAL, BOP, CSR, and BL between the groups (P> 0.05). Total amounts of PGE,, RANKL, RANK, OPG, and RANKL/OPG were not statistically significantly different between the groups (P> 0.05). The abundance of F. nucleatum, T. forsythia, P. intermedia, P. gingivalis, S. oralis and T. denticola was compared between the groups and the results were not statistically significant (P> 0.05). Conclusion: The results of this study suggested that PGE(2), TNF-alpha, RANKL, RANK, OPG, and RANKL/OPG in PICF, as well as microbiological parameters in submucosal biofilms, were similar between standard (>= 8 mm) and extra short (4 mm) implants. Therefore, the implant length does not seem to influence the bone loss, levels of osteoimmunological and microbiological markers in the peri-implant tissues and survival rates.en_US
dc.language.isoengen_US
dc.relation.isversionof10.15644/asc55/3/1en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental implantsen_US
dc.subjectImmunologyen_US
dc.subjectMicrobiologyen_US
dc.titleComparison of osteoimmunological and microbiological parameters of extra short and longer implants loaded in the posterior mandible: A split mouth randomized clinical studyen_US
dc.typearticleen_US
dc.contributor.departmentALKÜ, Fakülteler, Diş Hekimliği Fakültesi, Periodontoloji Ana Bilim Dalıen_US
dc.identifier.volume55en_US
dc.identifier.issue3en_US
dc.identifier.startpage238en_US
dc.identifier.endpage247en_US
dc.relation.journalActa Stomatologica Croaticaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster