Basit öğe kaydını göster

dc.contributor.authorÇolpak, Emine Dilara
dc.contributor.authorGümüş, Hasan Önder
dc.date.accessioned2021-02-19T21:16:19Z
dc.date.available2021-02-19T21:16:19Z
dc.date.issued2020
dc.identifier.issn0893-2174
dc.identifier.issn1942-4426
dc.identifier.urihttps://doi.org/10.11607/ijp.6581
dc.identifier.urihttps://hdl.handle.net/20.500.12868/375
dc.descriptionWOS: 000548652700007en_US
dc.descriptionPubMed: 32639700en_US
dc.description.abstractPurpose: To investigate the reverse torque values of abutment screws subjected to various surface modifications. Materials and Methods: Sixty abutment screws were divided into two groups of 30 each: with thermomechanical cycling (240,000 cycles) and without thermomechanical cycling. Each group was then divided into three subgroups according to surface treatment: nontreated (NT, n = 10); anodic oxidation (AO, n = 10); and diamond-like carbon (DLC) coating (DLC, n = 10). All abutment screws were tightened to 30 Ncm using a digital torque meter. The reverse torque values of the abutment screws with and without thermomechanical cycling were then measured. The percentage of deviation (PERDEV) for reverse torque values was calculated. Two-way analysis of variance followed by Tukey Honest Significant Difference test were used for intergroup comparisons. Results: Significant differences were found among the PERDEV values of the groups based on thermomechanical cycling and surface treatment (P < .001 for each). A significant interaction was found between surface treatment and thermomechanical cycling (P < .001). Conclusion: Reverse torque values of abutment screws were found to be higher after surface treatments. The abutment screws with AO exhibited the lowest torque value loss in groups with and without thermomechanical cycling.en_US
dc.description.sponsorshipErciyes University Scientific Research Projects Coordination UnitErciyes University [TDH-2018-8144]en_US
dc.description.sponsorshipThis work was supported by the Erciyes University Scientific Research Projects Coordination Unit (grant no: TDH-2018-8144). The authors would like to thank Dr Halis Ali Colpak and Dr Haydar Albayrak for their valuable contributions to the editing stage of this study. Additionally, they are eager to thank to Dr Oktay Bug. ra Topuz for his support in the experimental stage.; Further details of DLC surface modification were not given for publication by Oerlikon Balzers, which supported the DLC experimental group in this study.en_US
dc.language.isoengen_US
dc.publisherQuintessence Publishing Co Incen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEffect of surface modifications of abutment screws on reverse Torque values: An in vitro studyen_US
dc.typearticleen_US
dc.contributor.departmentALKÜen_US
dc.contributor.institutionauthor0-belirlenecek
dc.identifier.doi10.11607/ijp.6581
dc.identifier.volume33en_US
dc.identifier.issue4en_US
dc.identifier.startpage401en_US
dc.identifier.endpage409en_US
dc.relation.journalInternational Journal of Prosthodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster