dc.contributor.authorMohammad Sadeghi, Majid
dc.contributor.authorKeçeci, Emin Faruk
dc.contributor.authorKapıcıoğlu, Mehmet
dc.contributor.authorAralaşmak, Ayşe
dc.contributor.authorTezgel, Okan
dc.date.accessioned2023-10-02T06:35:35Z
dc.date.available2023-10-02T06:35:35Z
dc.date.issued2022en_US
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85125426933&origin=resultslist&sort=plf-f&src=s&nlo=&nlr=&nls=&sid=20c4fe371b9b908d4f7e419f791331ff&sot=aff&sdt=cl&cluster=scofreetoread%2c%22all%22%2ct&sl=72&s=AF-ID%28%22Alanya+Alaaddin+Keykubat+University%22+60198720%29+AND+SUBJAREA%28MEDI%29&relpos=61&citeCnt=1&searchTerm=
dc.identifier.urihttps://hdl.handle.net/20.500.12868/2371
dc.description.abstractIntroduction: Incorrect positioning is one of the main factors for glenoid component loosening in reverse shoulder arthroplasty and component placement can be challenging. This study aimed to assess whether Patient-Specific Instrumentation (PSI) provides better guide pin positioning accuracy and is superior to standard guided and freehand instrumentation methods in cases of glenoid bone deformity. Materials and Methods: Based on the Walch classification, five different scapula types were acquired by computed tomography (CT). For each type, two different surgeons placed a guide pin into the scapula using three different methods: freehand method, conventional non-patient-specific guide, and PSI guide. Each method was repeated five times by both surgeons. In these experiments, a total of 150 samples of scapula models were used (5 × 2 × 3 × 5 = 150). Post-operative CT scans of the samples with the guide pin were digitally assessed and the accuracy of the pin placement was determined by comparison to the preoperative planning on a three-dimensional (3D) model. Results: The PSI method showed accuracies to the preoperative plan of 2.68 (SD 2.10) degrees for version angle (p <.05), 2.59 (SD 2.68) degrees for inclination angle (p <.05), and 1.55 (SD 1.26) mm for entry point offset (p [removed]en_US
dc.language.isoengen_US
dc.relation.isversionof10.1177/10225536221079432en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectReverse shoulder arthroplastyen_US
dc.subjectPatient-specific guidesen_US
dc.subjectPreoperative planningen_US
dc.subjectGuide pin positioningen_US
dc.subjectImage processingen_US
dc.titleThree dimensional patient-specific guides for guide pin positioning in reverse shoulder arthroplasty: An experimental study on different glenoid typesen_US
dc.typearticleen_US
dc.contributor.departmentALKÜ, Fakülteler, Rafet Kayış Mühendislik Fakültesi, Endüstri Mühendisliği Bölümüen_US
dc.identifier.volume30en_US
dc.identifier.issue1en_US
dc.relation.journalJournal of Orthopaedic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US