Basit öğe kaydını göster

dc.contributor.authorDemetoğlu, Umut
dc.contributor.authorOcak, Hakan
dc.contributor.authorSongür, Timur
dc.contributor.authorÇolpak, Halis Ali
dc.date.accessioned2022-09-19T12:29:36Z
dc.date.available2022-09-19T12:29:36Z
dc.date.issued2021en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12868/1631
dc.description.abstractAim: The surface characteristics of an implant direct the wound healing and are an important factor for osteointegration. There are very few studies evaluating or comparing the clinical success of osteointegration of sandblasting with larger grit and acid etching (SLA) and rough surface as required by grit blasting (RBM) surfaces, which are important surface factors in selecting an implant. The aim of this study was to evaluate the osteointegration success in a total of 4793 implants in 2005 patients in SLA and RBM surface cylindrical implants of the same trademark and type. Material and Methods: A total of 4793 implants and 2005 patients composed of 943 females and 1062 males were included in this study. Regions of implant applications were grouped into anterior and posterior parts of the mandible and anterior and posterior parts of the maxilla and evaluated with success rates. Results: Among the implants, 1877 were RBM surface and the remaining 2675 had SLA surface. Seventy-four implants among the 1877 RBM surface implants failed (%96.06). The success rates were 94.75 % and 97.22%, maxilla and mandible, respectively. Among the 2675 SLA surface implants, 93 failed (%96.53). The success rates were 95.29% and 97.11% in maxilla and mandible, respectively. Discussion: Recently, the studies have demonstrated increased bone and implant contact areas and a high degree of osteoconductive property when applied to surfaces in histological studies. In the presented study, RBM and SLA surface implants with the same trademark and same design were clinically compared, and no significant difference was found between them in terms of osteointegration success.en_US
dc.language.isoengen_US
dc.relation.isversionof10.4328/ACAM.20436en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental implanten_US
dc.subjectImplant surfaceen_US
dc.subjectOsteointegrationen_US
dc.titleWhich dental implant surface is more effective in osteointegration: RBM surface versus SLA surfaceen_US
dc.typearticleen_US
dc.contributor.departmentALKÜ, Fakülteler, Diş Hekimliği Fakültesi, Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalıen_US
dc.identifier.volume12en_US
dc.identifier.issue7en_US
dc.identifier.startpage736en_US
dc.identifier.endpage739en_US
dc.relation.journalAnnals of Clinical and Analytical Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster